Scenario-Based Robustness of Proton Arc vs IMPT for Prostate SBRT Under Translational, Rotational, and Range Uncertainties
Document Type
Conference Proceeding
Publication Date
9-2026
Publication Title
International Journal of Particle Therapy
Abstract
Background and Aims: To quantify and compare scenario-based robustness of proton arc versus two-field IMPT for prostate SBRT under translational, rotational, and range uncertainties. Methods: Four prostate patients were retrospectively planned in RayStation (research version 2024A) using (1) DynamicARC delivered as a single partial arc (gantry: 325⁰ – 180⁰) and (2) IMPT with two parallel-opposed lateral fields. Nominal plans for both techniques were robustly optimized using ±5 mm setup (translational) and ±3.5% range uncertainties for total dose of 36.25 Gy(RBE) in 5 fractions. Robustness evaluation comprised 37 scenarios/plan: nominal (1); translational x/y/z ±5 mm (6); rotation-only perturbations ±3° yaw/pitch/roll (6); and range-coupled combinations with ρ ±3.5% for translational×range (12) and rotation×range (12). Target endpoints included CTV D95%, D98%, D99%, and D0.03cc. OAR robustness used RTOG 0938 dose–volume limits as evaluation thresholds across all scenarios, summarized by pooled and endpoint-level exceedance rates. Results: Nominal Target coverage was similar in both nominal DynamicARC and IMPT planning. Both of them met RTOG 0938 OAR constraints; any OAR failures occurred only during scenario-based robustness evaluation. Under uncertainties, worst-case CTV D95% was 35.41±0.28 Gy(RBE) (DynamicARC) and 35.38±0.68 Gy(RBE) (IMPT), meeting the robustness criterion (D95%≥95%). Worst-case CTV D99% was 34.34±0.33 Gy(RBE) for DynamicARC versus 33.68±1.20 Gy(RBE) for IMPT, consistent with greater degradation and variability for IMPT at D98%–D99%. Worst-case target coverage was driven by different perturbation types: for DynamicARC plan, worst-case CTV D95%–D99% occurred under rotation×range scenarios, whereas for IMPT it occurred under translational×range scenarios (across patients and coverage endpoints). IMPT reduced the worst-case target hotspot relative to DynamicARC (39.92±0.88 vs 40.50±0.48 Gy(RBE)). Across all OAR checks in robustness evaluation, pooled per-check failure rates were 4.64% (DynamicARC) and 6.71% (IMPT). OAR failures clustered in range-coupled perturbations—particularly translational×- range—and were driven primarily by rectum dose–volume constraints for IMPT, whereas DynamicARC failures were more frequently associated with bladder high-dose constraints. Conclusions: In this pilot robustness study, DynamicARC showed less degradation in worst-case D98%–D99% target coverage and lower overall OAR failure rates under robustness evaluation, while IMPT demonstrated lower worst-case target hotspot. The observed technique-dependent patterns of worst-case coverage suggest technique-specific robustness evaluation and warrant confirmation in larger cohorts.
Volume
21
Issue
Suppl
First Page
101698
Last Page
101698
Recommended Citation
Rana S, Padannayil NM, Poyil RC, Ding X, Shrestha N, Moktan H, et al. Scenario-based robustness of proton arc vs IMPT for prostate SBRT under translational, rotational, and range uncertainties. Int J Part Ther. 2026 Sep;21(Suppl):101698. doi:10.1016/j.ijpt.2026.101698
DOI
10.1016/j.ijpt.2026.101698
Comments
PTCOG 64 Particle Therapy Co-Operative Group 64th Annual Conference, June 8-13, 2026, Deauville, France