Real-World Radiotherapy and Healthcare Utilization in Patients Implanted With Cardiac Implantable Electronic Devices
Document Type
Conference Proceeding
Publication Date
11-2025
Publication Title
European Heart Journal
Abstract
Background: Radiotherapy (RT) is an effective treatment for certain malignancies. Patients implanted with cardiovascular implantable electronic devices (CIEDs) indicated for RT require additional considerations in treatment planning, such as device relocation and reprogramming. An increase in CIED radiation tolerance could ameliorate these considerations, however, the current-state implications of CIEDs on RT treatment pathways and healthcare utilization have not been quantified. Purpose: To quantify RT utilization in patients with CIEDs, the differential rates of RT utilization between cancer patients with and without CIEDs, and the differential CIED-related healthcare utilization between cancer patients with and without RT. Methods: The Optum Clinformatics© 2007-2022 claims database was used to identify patients with CIEDs and cancers treated with RT. RT use and CIED-related actions (device revision, replacement, removal, re-programming, and interrogation), were identified via procedure codes. Cox models were used to compare RT utilization between patients with and without CIEDs, and logistic and Poisson models were used to compare CIED actions between cancer patients with and without RT. All results were adjusted for patient demographics, and cancer and CIED type. Results: Three mutually exclusive cohorts were identified: CIED patients with cancer (N=17,314), non-CIED patients with cancer (N=600,460), and CIED patients with no evidence of cancer (N=295,711). During a follow-up of up to 15.2 years after implant, 9.4% of all patients with CIEDs received RT. Among cancer patients, those with CIED were marginally more likely to receive RT the year after diagnosis than those without CIED (adj. HR=1.06, 95% CI 1.03-1.10; Figure 1). CIED patients who received RT had more CIED-related actions compared to those who did not receive RT (device replacement: 3.7% vs 2.5%, p=0.0002; revision: 0.8% vs 0.4%, p=0.0004; device programming/year: 1.0 vs 0.6, p< .0001; interrogation/year: 1.0 vs. 0.6, p< .0001; Figure 2); this corresponds to a projected 8 additional procedures and 330 additional device checks in 500 CIED patients with cancer. Conclusion: Among patients with cancer, CIED patients were as likely to receive RT as those without a CIED, indicating that CIEDs were not an obstacle to guideline-indicated care. CIED patients with RT have an increased use of device-related healthcare utilization, which could be avoided with increased radiation tolerance labeling.
Volume
46
Issue
Suppl 1
Recommended Citation
Love CJ, Higuera L, Rosemas SC, Wilkinson JD, Mehta NK. Real-world radiotherapy and healthcare utilization in patients implanted with cardiac implantable electronic devices. Eur Heart J. 2025 Nov;46(Suppl 1). doi:10.1093/eurheartj/ehaf784.869
DOI
10.1093/eurheartj/ehaf784.869

Comments
European Society of Cardiology (ESC) Congress 2025 together with World Congress of Cardiology, August 29 - September 1, 2025, Madrid, Spain