Single-Port Robotic Mitral Valve Repair: First-in-Human Technique and 30-Day Outcome.
Document Type
Article
Publication Date
11-13-2026
Publication Title
JACC Case Rep
Abstract
BACKGROUND: Comprehensive mitral reconstruction has progressed from sternotomy to minithoracotomy, thoracoscopy, and multiport robotics.
FIRST-IN-HUMAN/EARLY REPORTS SUMMARY: A 59-year-old man with severe mitral regurgitation from flail middle scallop posterior mitral valve leaflet (P2) underwent single-port robotic repair using one non-rib-spreading instrument cannula and a separate accessory working port. Cardioplegic arrest, triangular resection, 2-layer reconstruction, and annuloplasty were completed with cross-clamp and bypass times of 62 and 123 minutes. He was discharged on day 3 and at 30 days was pain-free, active, and free of residual regurgitation.
DISCUSSION: Consolidating the camera and robotic instruments through 1 lateral cannula enabled intrathoracic triangulation and flexible endoscopic camera manipulation. This case establishes feasibility; however, superiority requires a comparative study.
NOVELTY: To the best of our knowledge, this is the first reported experience of lateral cannula single-port robotic mitral valve repair using this platform.
TAKE-HOME MESSAGE: Single-port robotic mitral repair through consolidated instrument access allows early clinical benefit and requires prospective validation.
First Page
111218
Last Page
111218
Recommended Citation
Suri RM, Comas G, Lau W, Haddad A, Schwann T, Young J et al. [Bloomingdale R, Gallagher M.] Single-Port Robotic Mitral Valve Repair: First-in-Human Technique and 30-Day Outcome. JACC Case Rep. 2026 Nov 13:111218. doi: 10.1016/j.jaccas.2026.111218. Epub ahead of print. PMID: 43033178.
DOI
10.1016/j.jaccas.2026.111218
ISSN
2666-0849
PubMed ID
43033178